The domestically produced supercritical units currently designed are all equipped with pre filters. The pre filter is equipped with foldable filter elements, which means a certain number of filter elements are installed inside the filter. The condensed water flows out through the porous tube in the center of the filter element, and impurities are trapped on the surface of the filter element. The accuracy of the filter element is 10 μ m during unit start-up, and 1 μ m or 4 μ m during normal operation.
Our company has developed a foldable filter element based on years of experience in the development of filtration and separation technology products and reference to foreign materials. It can effectively control solid pollutants such as metals and silicon in condensed water, avoid the formation of dissolved oxides in the high-temperature state after unit start-up, greatly reduce the start-up time of the unit, and effectively shorten the time for water quality to meet standards during unit start-up.
performance parameter
Serial number | name | Activate the filter element | Working filter element |
1 | Filter element shape | 2.5“ ×70“ | 2.5 ”×70 ” |
2 | Filter element material | PP | PP |
3 | Filter element rack | strengthenPP | strengthenPP |
4 | Filtering accuracy | 5μm,10μm | 1μm,4μm |
5 | Filter element form | Folding type | Folding type |
6 | Maximum operating temperature | 60℃~ 80℃ | 60℃~ 80℃ |
7 | Design traffic | 5.6m³/h/root | 5.6m³/h/root |